Kliniska Bevis We are proud to present a collection of different surgeon experiences that have been published in peer-reviewed journals sharing their remarkable safety results achieved with Motiva SmoothSilk® Implants. Glicksman C, Wolfe A, McGuire P. The Study of the Safety and Effectiveness of Motiva SmoothSilk Silicone Gel-Filled Breast Implants in Patients Undergoing Primary and Revisional Breast Augmentation: Three-Year Clinical Data. Aesthetic Surgery Journal. Published online September 27, 2024. doi:https://doi.org/10.1093/asj/sjae134 Sforza M, Zaccheddu R, Alleruzzo A et al. Preliminary 3-year evaluation of experience with SilkSurface and VelvetSurface Motiva silicone breast implants: a single-center experience with 5813 consecutive breast augmentation cases. Aesthet Surg J. 2018; 38(Suppl 2):S62-S73. doi: 10.1093/asj/sjx150 451 patients Primary Augmentation 2 fall av Kapselkontraktur 1 fall av Ruptur 4 fall av Infektion 14 cases of Felaktig placering 2506 patienter Uppföljningsperiod på 2 år 0 fall av Kapselkontraktur Ruptur Felaktig placering 1 fall av Infektion ÖPPNA ÖPPNA Glicksman C, Wolfe A, McGuire P. The Study of the Safety and Effectiveness of Motiva SmoothSilk Silicone Gel-Filled Breast Implants in Patients Undergoing Primary and Revisional Breast Augmentation: Three-Year Clinical Data. Aesthetic Surgery Journal. Published online September 27, 2024. doi:https://doi.org/10.1093/asj/sjae134 451 patients Primary Augmentation 2 fall av Kapselkontraktur 1 fall av Ruptur 4 fall av Infektion 14 cases of Felaktig placering ÖPPNA Sforza M, Zaccheddu R, Alleruzzo A et al. Preliminary 3-year evaluation of experience with SilkSurface and VelvetSurface Motiva silicone breast implants: a single-center experience with 5813 consecutive breast augmentation cases. Aesthet Surg J. 2018; 38(Suppl 2):S62-S73. doi: 10.1093/asj/sjx150 2506 patienter Uppföljningsperiod på 2 år 0 fall av Kapselkontraktur Ruptur Felaktig placering 1 fall av Infektion ÖPPNA Huemer GM, Wenny R, Aitzetmüller MM, Duscher D. Motiva Ergonomix Round SilkSurface Silicone Breast Implants: Outcome Analysis of 100 Primary Breast Augmentations over 3 Years and Technical Considerations. Plast Reconstr Surg. 2018;41(6):831e-842e. doi: 10.1097/PRS.0000000000004367 100 patienter Uppföljningsperiod på 1 år 0 fall av Infektion 1 fall av Kapselkontraktur Ruptur 4 fall av Felaktig placering ÖPPNA Huemer GM, Wenny R, Aitzetmüller MM, Duscher D. Motiva Ergonomix Round SilkSurface Silicone Breast Implants: Outcome Analysis of 100 Primary Breast Augmentations over 3 Years and Technical Considerations. Plast Reconstr Surg. 2018;41(6):831e-842e. doi: 10.1097/PRS.0000000000004367 Sim HB. Revisiting Prepectoral Breast Augmentation: Indications and Refinements, Aesth Surg J, sjy294 100 patienter Uppföljningsperiod på 1 år 0 fall av Infektion 1 fall av Kapselkontraktur Ruptur 4 fall av Felaktig placering 76 patienter Uppföljningsperiod på 1 år 0 fall av Kapselkontraktur Ruptur Infektion Felaktig placering ÖPPNA ÖPPNA Sim HB. Revisiting Prepectoral Breast Augmentation: Indications and Refinements, Aesth Surg J, sjy294 76 patienter Uppföljningsperiod på 1 år 0 fall av Kapselkontraktur Ruptur Infektion Felaktig placering ÖPPNA Chacón M, Chacón M & Fassero J. Six-Year Prospective Outcomes of Primary Breast Augmentation with Nano-Surface Implants. Aesthet Surg J. 2018; doi: 10.1093/asj/sjy196 35 patienter Uppföljningsperiod på 6 år 0 fall av Kapselkontraktur Ruptur Infektion Felaktig placering ÖPPNA Chacón M, Chacón M & Fassero J. Six-Year Prospective Outcomes of Primary Breast Augmentation with Nano-Surface Implants. Aesthet Surg J. 2018; doi: 10.1093/asj/sjy196 Hong P, Kim SS, Jeong C, et al. Four-Year Interim Results of the Safety of Augmentation Mammaplasty Using the Motiva Ergonomix™ Round SilkSurface: A Multicenter, Retrospective Study. Aesthetic Plastic Surgery. 2021. doi:10.1007/s00266-021-02152-3 35 patienter Follow-up period of 6 years 0 fall av Kapselkontraktur Ruptur Infektion Felaktig placering 873 patienter Uppföljningsperiod på 1,5 år 18 fall av Kapselkontraktur 6 fall av Infektion 9 fall av Felaktig placering ÖPPNA ÖPPNA Hong P, Kim SS, Jeong C, et al. Four-Year Interim Results of the Safety of Augmentation Mammaplasty Using the Motiva Ergonomix™ Round SilkSurface: A Multicenter, Retrospective Study. Aesthetic Plastic Surgery. 2021. doi:10.1007/s00266-021-02152-3 873 patienter Uppföljningsperiod på 1,5 år 18 fall av Kapselkontraktur 6 fall av Infektion 9 fall av Felaktig placering ÖPPNA Botti G, Botti C, Ciancio F. A single center’s clinical experience with ERGONOMIX breast implants. Aesthetic Surgery Journal. 2021. doi:10.1093/asj/sjab422 356 patienter Uppföljningsperiod på 3 år 2 fall av Kapselkontraktur 0 fall av Infektion Ruptur 1 fall av Felaktig placering ÖPPNA Botti G, Botti C, Ciancio F. A single center’s clinical experience with ERGONOMIX breast implants. Aesthetic Surgery Journal. 2021. doi:10.1093/asj/sjab422 Randquist C, Jager M, Stavrou D. Six-year evaluation of Motiva Round and Ergonomix SmoothSilk surface silicone breast implants: A two-center, two-surgeon outcome analysis of 1053 primary and secondary breast augmentations and augmentation mastopexy. Aesthet Surg J. 2022 Nov 9;sjac276. doi: 10.1093/asj/sjac276. Online ahead of print. 356 patienter Uppföljningsperiod på 3 år 2 fall av Kapselkontraktur 0 fall av Infektion Ruptur 1 fall av Felaktig placering 1053 patienter Uppföljningsperiod på 4 år 4 fall av Kapselkontraktur 2 fall av Ruptur 0 fall av Infektion 32 cases of Felaktig placering ÖPPNA ÖPPNA Randquist C, Jager M, Stavrou D. Six-year evaluation of Motiva Round and Ergonomix SmoothSilk surface silicone breast implants: A two-center, two-surgeon outcome analysis of 1053 primary and secondary breast augmentations and augmentation mastopexy. Aesthet Surg J. 2022 Nov 9;sjac276. doi: 10.1093/asj/sjac276. Online ahead of print. 1053 patienter Uppföljningsperiod på 4 år 4 fall av Kapselkontraktur 2 fall av Ruptur 0 fall av Infektion 32 cases of Felaktig placering ÖPPNA